Case Sharing | Application Case of High-Temperature Humidity Meter in Blanket Factory

2023-11-03 17:00

Case Sharing

Time: October 2023

Location: Liyang City, Jiangsu Province

Project: Monitoring of high-temperature humidity in a blanket factory in Liyang City

Equipment: DB43 high-temperature humidity meter



Product installation pictures


微信图片_20240219133354.jpg


Product introduction

微信图片_20240219133408.jpg

Feature:

① 316L stainless steel rod body, with strong corrosion resistance.

② Using original imported sensor chips, it effectively guarantees the accuracy of the instrument.

③ Withstanding temperature of 200 ℃, not afraid of high-temperature harsh environments.

④ Unique heating design, high-precision temperature automatic compensation, effectively preventing the solidification of sulfides.

⑤ Two-stage dust filtration design, effectively filtering dust and acidic liquids.


Application area

Paper mills, dyeing and printing factories, textile factories, rubber factories, ceramic factories, sizing and drying, tunnel drying, high and low temperature test chambers, drying boxes, hydrogen fuel cells, steam pipes, etc.


Technical parameters

  • Measurement principle: capacitance method

  • Display method: 4-digit digital tube display

  • Measuring range: Volume ratio: 0 ~ 40% VOL or relative humidity 0 ~ 100% RH (can also be customized and developed according to the humidity variable required by the customer)

  • Resolution: 0.1%

  • Measurement accuracy: <±1.5% FS

  • Repeatability: <±1%

  • Response time: T90 < 15S

  • Operating temperature: Instrument: -10 ~ +50℃, probe: 0 ~ 200℃

  • Heating type: Electric heating (optional) Heating temperature: 50℃ ~ 150℃

  • Sampling method: Direct insertion

  • Analog output: 4-20mA DC (non-isolated output, load resistance < 500 ohms)

  • Other interfaces: RS485

  • Power supply: DC 24V±10%, power consumption < 2.5A

  • Protection: Probe is 316L, and the protection level of the instrument box is IP54

  • Service life: Probe > 36 months; Sensor > 24 months (under normal use conditions)

  • Sample gas components: No flammable gas, no highly corrosive gas

  • Probe length: Insertion depth 225mm (customizable)

  • Installation method: Insertion type, flange type installation

name: